CAT6 U/UTP 1101-04004MB Network Cable – Gray

Features

  • Conductor sizes for Cat.6 are set at 23AWG
  • By keeping the gauge size of the conductor larger, there is less heat generation caused and less drop of voltage over distance
  • Capable of handling the latest version of power over Ethernet
  • Cable has been tested over 500Mhz and has shown performance testing results allowing 10Gbit Ethernet transmission up to a length of 70mtrs

Applications

  • Voice; T1; ISDN
  • 100BASE-T Ethernet (IEEE802.3)
  • 155/622Mbps 1.2/2.4 Gbps ATM
  • 1000Mbps Gigabit Ethernet
  • 550MHz Broadband Video

Standards Conformance

  • ACMA approved to AS/CA S008 
  • ISO/IEC11801 2nd edition CLASS E
  • ANSI/TIA-568-2.D standard
  • CENELEC EN 50173-1, CENELEC
  • PoE++ & 4PPoE – IEEE 802.3bt level 3 & 4
  • Flame Rated: CM

Independent Verified Certifications

  • ETL verified to ANSI/TIA-568-2.D Category 6 102661868CRT-001b
  • ACMA approved to AS/CA S008 

Performance Statistics

Frequency Mhz Insertion Loss dB/100mtrs NEXT (dB) Return Loss (dB)
1 1.8 78.0 37.8
4 3.0 76.0 36.5
10 5.2 70.0 31.0
16 6.8 68.0 31.0
20 7.6 64.0 31.0
31.25 9.3 62.5 30.0
62.5 13.2 60.0 30.0
100 18.1 57.0 29.0
200 26.1 52.5 27.0
250 28.9 50.0 25.1
300 31.8 46.0 23.4
400 36.5 43.0 21.9
500 41.8 42.0 20.6

Ordering Information

Product Number Product Name Jacket Type Color Length Qty
1101-04004MB PowerMAX500 Cat.6 U/UTP 23AWG PVC Cable – Gray PVC Gray 305m / Box
1101-04442 PowerMAX500 Cat.6 U/UTP 23AWG PVC Cable – Blue PVC Blue 305m / Box
1101-04006CH PowerMAX500 Cat.6 U/UTP 23AWG PVC Cable – Green PVC Green 305m / Box

Technical Specifications

Construction

Conductor
Material Bare Copper
Wire Size 23AWG
Insulation
Material PE
Thickness Nominal: 1.011 mm
Colors Blue/White-Blue | Orange/White-Orange | Green/White-Green | Brown/White-Brown
Unaged Elongation(%) Min. 300%
Unaged Tensile Strength Min. 1.683 Kgf/mm²
Jacket
Material Flame Retardant PVC
Thickness 0.5 ± 0.02 mm
Diameter 6.0 ± 0.2 mm
Color Gray (assorted upon request)
Fire Rated Class CM

Physical Ranges

Insulation
Min. Tension Strength Before Aging : Min. 1.683 Kgf/mm² | After Aging : 75% before aging (100℃ X 48hrs)
Min Elongation (%) Before Aging : 300% | After Aging : 75% before aging (100℃ X 48hrs)
Jacket
Min. Tension Strength Before Aging : Min. 1.407 Kgf/mm² | After Aging : 75% before aging (100℃ X 168hrs)
Min Elongation (%) Before Aging : Min. 100% | After Aging : 50% before aging (100℃ X 168hrs)
Cold Bend Test -20 ± 2℃ x 4hrs no. crack
Dielectric Strength 2500 V dc / 2 seconds
Min. Bending Radius 50 mm
Max. Pulling Tension 25 lbs
Installation Temperature 0℃ to +50℃
Operating Temperature -20℃ to +70℃

Electrical

Conductor Resistance Max. 7.32 Ω/100m at 20℃
DC Resistance Unbalance Max. 2%
Pair-to-Ground Capacitance Unbalance Max. 160 pF/100m
Dielectric Strength of Insulation 2500 V dc / 2 seconds
Insulation Resistance Test Min. 5000 MΩ·Km
Mutual Capacitance Max. 5600 pF/100m
Impedance 1~100MHz 100Ω ± 15%
Impedance 100-250MHz 100Ω ± 22%