Standards Conformance
- ACMA approved to AS/CA S008 
 
- ISO/IEC11801 2nd edition CLASS E
 
- ANSI/TIA-568-2.D standard
 
- CENELEC EN 50173-1, CENELEC
 
- PoE++ & 4PPoE – IEEE 802.3bt level 3 & 4
 
- Flame Rated: CM
 
Independent Verified Certifications
- ETL verified to ANSI/TIA-568-2.D Category 6 102661868CRT-001b
 
- ACMA approved to AS/CA S008 
 

Performance Statistics
 | 
| Frequency Mhz | 
Insertion Loss dB/100mtrs | 
NEXT (dB) | 
Return Loss (dB) | 
| 1 | 
1.8 | 
78.0 | 
37.8 | 
| 4 | 
3.0 | 
76.0 | 
36.5 | 
| 10 | 
5.2 | 
70.0 | 
31.0 | 
| 16 | 
6.8 | 
68.0 | 
31.0 | 
| 20 | 
7.6 | 
64.0 | 
31.0 | 
| 31.25 | 
9.3 | 
62.5 | 
30.0 | 
| 62.5 | 
13.2 | 
60.0 | 
30.0 | 
| 100 | 
18.1 | 
57.0 | 
29.0 | 
| 200 | 
26.1 | 
52.5 | 
27.0 | 
| 250 | 
28.9 | 
50.0 | 
25.1 | 
| 300 | 
31.8 | 
46.0 | 
23.4 | 
| 400 | 
36.5 | 
43.0 | 
21.9 | 
| 500 | 
41.8 | 
42.0 | 
20.6 | 
 
 
 
Ordering Information
 | 
| Product Number | 
Product Name | 
Jacket Type | 
Color | 
Length Qty | 
| 1101-04004MB | 
PowerMAX500 Cat.6 U/UTP 23AWG PVC Cable – Gray | 
PVC | 
Gray | 
305m / Box | 
| 1101-04442 | 
PowerMAX500 Cat.6 U/UTP 23AWG PVC Cable – Blue | 
PVC | 
Blue | 
305m / Box | 
| 1101-04006CH | 
PowerMAX500 Cat.6 U/UTP 23AWG PVC Cable – Green | 
PVC | 
Green | 
305m / Box | 
Technical Specifications
 | 
Construction
 | 
| Conductor | 
 | 
| Material | 
Bare Copper | 
| Wire Size | 
23AWG | 
| Insulation | 
 | 
| Material | 
PE | 
| Thickness | 
Nominal: 1.011 mm | 
| Colors | 
Blue/White-Blue | Orange/White-Orange | Green/White-Green | Brown/White-Brown | 
| Unaged Elongation(%) | 
Min. 300% | 
| Unaged Tensile Strength | 
Min. 1.683 Kgf/mm² | 
| Jacket | 
 | 
| Material | 
Flame Retardant PVC | 
| Thickness | 
0.5 ± 0.02 mm | 
| Diameter | 
6.0 ± 0.2 mm | 
| Color | 
Gray (assorted upon request) | 
| Fire Rated Class | 
CM | 
Physical Ranges
 | 
| Insulation | 
 | 
| Min. Tension Strength | 
Before Aging : Min. 1.683 Kgf/mm² | After Aging : 75% before aging (100℃ X 48hrs) | 
| Min Elongation (%) | 
Before Aging : 300% | After Aging : 75% before aging (100℃ X 48hrs) | 
| Jacket | 
 | 
| Min. Tension Strength | 
Before Aging : Min. 1.407 Kgf/mm² | After Aging : 75% before aging (100℃ X 168hrs) | 
| Min Elongation (%) | 
Before Aging : Min. 100% | After Aging : 50% before aging (100℃ X 168hrs) | 
| Cold Bend Test | 
-20 ± 2℃ x 4hrs no. crack | 
| Dielectric Strength | 
2500 V dc / 2 seconds | 
| Min. Bending Radius | 
50 mm | 
| Max. Pulling Tension | 
25 lbs | 
| Installation Temperature | 
0℃ to +50℃ | 
| Operating Temperature | 
-20℃ to +70℃ | 
Electrical
 | 
| Conductor Resistance | 
Max. 7.32 Ω/100m at 20℃ | 
| DC Resistance Unbalance | 
Max. 2% | 
| Pair-to-Ground Capacitance Unbalance | 
Max. 160 pF/100m | 
| Dielectric Strength of Insulation | 
2500 V dc / 2 seconds | 
| Insulation Resistance Test | 
Min. 5000 MΩ·Km | 
| Mutual Capacitance | 
Max. 5600 pF/100m | 
| Impedance 1~100MHz | 
100Ω ± 15% | 
| Impedance 100-250MHz | 
100Ω ± 22% |