Technical Specifications |
Construction |
Conductor |
|
Material |
Solid Bare Copper |
Wire Size |
24AWG |
Insulation |
|
Material |
HDPE |
Thickness |
Nominal: 0.275 mm |
Diameter |
1.05±0.05mm |
Colors |
Blue/White-Blue | Orange/White-Orange | Green/White-Green | Brown/White-Brown |
Drain Wire |
26AWG Tinned Copper drain wire |
Jacket |
|
Material |
Flame Retardant PVC |
Thickness |
0.5mm±0.02 mm |
Diameter |
6.0±0.5mm |
Color |
Gray |
Shielding |
Maylar film as a layer of buffer / Aluminum-foil-laminated shield |
Physical Ranges |
Jacket |
|
Min. Tension Strength |
Before Aging : Min 1500psi | After Aging : 75% of before aging |
Min Elongation (%) |
Before Aging : Min 100% | After Aging : Min. elongation retention: 50% |
Dielectric Strength |
2500Vds/3 seconds |
Min. Bending Radius |
25mm |
Max. Pulling Tension |
25lb / Mtr (8-10kg) |
Installation Temperature |
0℃ to +50℃ |
Operating Temperature |
-20℃ to +70℃ |
Electrical |
Conductor Resistance |
9.38Ω/100m at 20 |
DC Resistance Unbalance |
Max. % |
Pair-to-Ground Capacitance Unbalance |
Max. 330pf/100m |
Dielectric Strength of Insulation |
DC 500V / 1min or AC 350V / 1min |
Insulation Resistance Test |
Min. 150MΩ/Km |
Mutual Capacitance |
Max. 5600 pF/100m |
Impedance 1 ~ 125Mhz |
100Ω±15% |