CAT6A S/FTP 1105-06008 Network Cable

Application

  • 10GBASE-T Ethernet
  • 100BASE-TX Fast Ethernet
  • 1000BASE-TX Gigabit Ethernet
  • 1000BASE-T Gigabit Ethernet
  • 10BASE-TX Ethernet
  • ATM CB1G
  • 155/622 Mbps ATM
  • 100 Mbps TP-PMD
  • 100VG-AnyLAN

Standards Conformance

  • UL Listed
  • CENELEC EN 50173-1, CENELEC EN 50288-10-1
  • ISO/IEC 2nd Edition 11801 Class EA
  • IEC 3rd Edition 61935-1, IEC 2nd edition 61156-5
  • All proposed Cat.6A requirements as per ANSI/TIA, ISO/IEC, and CENELEC EN Standard ANSI/TIA-568-2.D Cat.6A
  • 3P certified for Cat.6A S/FTP installation cable
  • Flame Retardancy is verified according to IEC 60332-1-2
  • Implemented ROHS Compliance for the Requirement of European Union Issued Directive 2002/95/EC

 

Performance Statistics

Frequency Mhz Insertion Loss dB/100mtrs NEXT (dB) Return Loss (dB)
1 2.1 75.3 20.0
4 3.8 66.3 23.0
10 5.9 60.3 25.0
16 7.5 57.2 25.0
20 8.4 55.8 25.0
31.25 10.5 52.9 23.6
62.5 15 48.4 21.5
100 19.1 45.3 20.1
200 27.6 40.8 18.0
250 31.1 39.3 17.3
300 34.3 38.1 17.3
400 40.1 36.3 17.3
500 45.3 34.8 17.3

Ordering Information

Product Number Product Name Jacket Type Color Length Qty
1105-06008 PowerMAX+ Cat.6A S/FTP 23AWG PVC Cable PVC Gray 305m / Reel
1105-06002 PowerMAX+ Cat.6A S/FTP 23AWG LSZH Cable LSZH Gray 305m / Reel

Technical Specifications

Construction
Conductor
Material Pure Annealed Copper
Wire Size 23AWG
Insulation
Material Foam-Skin PE
Thickness Nominal: 0.419
Colors Blue/White-Blue | Orange/White-Orange | Green/White-Green | Brown/White-Brown
Unaged Elongation (%) Min. 100%
Unaged Tensile Strength Min. 0.816 Kgf/mm²
Jacket
Material PVC
Thickness 0.5 mm
Diameter 7.4 mm
Color Gray
Screen Material Aluminum-Mylar tape and tinned copper braid
Physical Ranges
Insulation
Min. Tension Strength Before Aging : 0.816 Kgf/mm²
Min Elongation (%) Before Aging : Min 100%
Jacket
Min. Tension Strength Before Aging : Min. 1.407 Kgf/mm² | After Aging : 75% (PVC) at 100℃ X 168Hrs)
Min Elongation (%) Before Aging : 100% | After Aging : 50% at 100℃ X 168Hrs
Cold Bend Test -20 ± 20C X 4hrs no. crack
Dialectric Strength 1500 V dc/ 2 seconds
Min. Bending Radius 40mm
Max. Pulling Tension 8-10kg (25lbs)
Installation Temperature -10℃ to +60℃
Operating Temperature -10℃ to +60℃
Electrical
Conductor Resistance Max. 9.38 Ω/100m at 200℃
DC Resistance Unbalance 2% max
Pair-to-Ground Capacitance Unbalance 160 pF/100m
Dielectric Strength of Insulation AC 1.7 KV for 2 s
Insulation Resistance Test Min. 5000MΩ/m
Mutual Capacitance 5.6nF/100m
Impedance 1~500MHz 100Ω ± 15%