CAT6 U/UTP 1101-04023 Network Cable

Features

  • Conductor sizes for Cat.6 are set at 23AWG
  • By keeping the gauge size of the conductor larger, there is less heat generation caused and less drop of voltage over distance
  • Capable of handling the latest version of power over ethernet
  • Cable has been tested over 500Mhz and has shown performance testing results allowing 10Gbit Ethernet transmission up to a length of 70mtrs

Applications

  • Voice; ISDN
  • 100BASE-T Ethernet (IEEE802.3)
  • 155/622Mbps 1.2/2.4 Gbps ATM
  • 1000Mbps Gigabit Ethernet
  • 550MHz Broadband Video

Standards Conformance

  • ACMA approved to AS/CA S008 
  • ISO/IEC11801 2nd edition CLASS E
  • ANSI/TIA-568-2.D standard
  • CENELEC EN 50173-1, CENELEC
  • PoE++ & 4PPoE – IEEE 802.3bt level 3 & 4
  • Flame Rated: CM

Independent Verified Certifications

    • Verified to ANSI/TIA-568-2.D Cat.6 102661868CRT-001b
    • ACMA approved to AS/CA S008 

Performance Statistics

Frequency Mhz Insertion Loss dB/100mtrs NEXT (dB) Return Loss (dB)
1 2.0 74.3 72.3
4 3.8 65.3 63.3
10 6.0 59.3 57.3
16 7.6 56.2 54.2
20 8.5 54.8 52.8
31.25 10.7 51.9 49.9
62.5 15.4 47.4 45.4
100 19.8 44.3 42.3
200 29.0 39.8 37.8
250 32.8 38.3 36.3

Ordering Information

Product Number Product Name Jacket Type Color Length Qty
1101-04023 PowerMAX500 Cat.6 U/UTP 23AWG PVC Cable – 100Mtr PVC Gray 100m / Box
1101-04041 PowerMAX500 Cat.6 U/UTP 23AWG LSZH Cable – 100Mtr LSZH Gray 100m / Box

Technical Specifications

Construction

Conductor
Material Bare Copper
Wire Size 23AWG
Insulation
Material PE
Thickness Nominal: 1.011 mm
Colors Blue/White-Blue | Orange/White-Orange | Green/White-Green | Brown/White-Brown
Unaged Elongation(%) Min. 300%
Unaged Tensile Strength Min. 1.683 Kgf/mm²
Jacket
Material Flame Retardant PVC
Thickness 0.5 ± 0.02 mm
Diameter 6.0 ± 0.2 mm
Color Gray (assorted upon request)
Fire Rated Class CM

Physical Ranges

Insulation
Min. Tension Strength Before Aging : Min. 1.683 Kgf/mm² | After Aging : 75% before aging (100℃ X 48hrs)
Min Elongation (%) Before Aging : 300% | After Aging : 75% before aging (100℃ X 48hrs)
Jacket
Min. Tension Strength Before Aging : Min. 1.407 Kgf/mm² | After Aging : 75% before aging (100℃ X 168hrs)
Min Elongation (%) Before Aging : Min. 100% | After Aging : 50% before aging (100℃ X 168hrs)
Dielectric Strength 2500 V dc / 2 seconds
Min. Bending Radius 50 mm
Max. Pulling Tension 25 lbs
Installation Temperature 0℃ to +50℃
Operating Temperature -20℃ to +70℃

Electrical

Conductor Resistance Max. 7.32 Ω/100m at 20℃
DC Resistance Unbalance Max. 2%
Pair-to-Ground Capacitance Unbalance Max. 160 pF/100m
Dielectric Strength of Insulation 2500 V dc / 2 seconds
Insulation Resistance Test Min. 5000 MΩ·Km
Mutual Capacitance Max. 5600 pF/100m
Impedance 1~100MHz 100Ω ± 15%
Impedance 100-250MHz 100Ω ± 22%